Data Centers Have a Water Problem. Cooling Can Fix It.

Updated: November 13, 2026

Water is becoming a deciding factor in where and how data centers are built. A facility’s water footprint sits in two places: the power plant that generates its electricity and the cooling system inside.  

U.S. data centers directly consumed 17.4 billion gallons of water in 2023, while the electricity they used consumed about 12 times more. With more than 200 state bills introduced in 2025 and some local governments restricting evaporative cooling, waterless cooling and energy efficiency now shape both water impact and site approval.

LinkedIn
Data Centers Have a Water Problem. Cooling Can Fix It.

Where the water goes, why it has become a siting issue, and what waterless cooling changes?

Water is no longer a background engineering consideration in data center development. It is increasingly part of the conversation around site selection, permitting, and long-term operations.

To understand a data center’s water footprint, follow the water to two places: the power plant that generates the electricity and the cooling system operating inside the facility.

Electricity carries a water cost

Most U.S. power plants generate electricity by heating water into steam. Once that steam drives a turbine, it must be cooled and condensed before it can be reused. That cooling process requires water.

At plants with wet cooling towers, 3% to 5% of the circulating water evaporates. These towers serve more than 60% of U.S. thermoelectric capacity as per a report by the Information Technology and Innovation Foundation (ITIF).

Data centers are consuming a growing share of this electricity. Lawrence Berkeley National Laboratory (LBNL) estimates that U.S. data centers consumed 192 TWh in 2024, representing 4.7% of national electricity use. Its reference case projects consumption will reach 649 TWh by 2030, or approximately 11.8% of total U.S. electricity use.

Under that projection, data centers would account for roughly one-third of all U.S. load growth between 2024 and 2030.

How much water do data centers use?

LBNL estimates that U.S. data centers directly consumed 17.4 billion gallons of water in 2023, primarily for cooling. Generating the electricity used by those facilities consumed approximately 211 billion gallons more, about 12 times the direct amount.

Together, direct and indirect data center water consumption still represents less than 1% of total U.S. water consumption as per the ITIF report.

However, location can matter as much as total volume. The amount of water consumed per kilowatt-hour of electricity ranges from approximately 2.1 gallons in the hydropower-heavy Pacific Northwest to about 0.13 gallons in solar-heavy California.

At the national level, the issue is not one of overall water shortage. The picture changes in arid regions such as the Southwest, where water concerns are most acute.

Why water has become a siting issue?

Policy around data center development is moving quickly. In 2025, more than 200 data center-related bills were introduced across all 50 states, and more than 40 became law. Moratoria are under discussion in more than 20 states (ITIF).

Minnesota became the first state to require formal water permitting for large data centers, with stricter review for projects in water-stressed watersheds.

Some local governments are going further by regulating cooling technology itself. Referencing an article in The Sentinel Colorado: In August 2026, the Aurora, Colorado, city council rejected a proposed data center moratorium. Instead, it advanced rules that include a prohibition on evaporative cooling for future developments.

What is waterless data center cooling?

Waterless data center cooling rejects heat without evaporating water. Instead of relying on cooling towers, it uses refrigerant-based or dry heat rejection. As a result, the facility does not need an ongoing water supply for cooling.

The remaining water impact is indirect: the water used to generate the electricity that powers the facility.

Energy efficiency is also water efficiency

Indirect water use represents the larger share of a data center’s water footprint. That means every kilowatt-hour of electricity saved also reduces upstream water consumption.

Across the industry, data center power usage effectiveness, or PUE, improved from 1.55 in 2018 to 1.45 in 2024. LBNL attributes this improvement primarily to growth in facilities using liquid cooling for AI servers.

Free cooling with ambient air and efficient compressor operation at partial load can extend the same benefit.

Questions to ask when evaluating cooling

When assessing a cooling strategy, consider these questions:

  • How much water will the cooling system consume each year at the specific site?

  • What is the water intensity of electricity in the region?

  • Could the design pass a local review that restricts evaporative cooling?

Cooling decisions are becoming siting decisions

Lennox designed PhaseFlow for this operating environment. It uses a waterless, closed-loop refrigerant architecture with a low-GWP refrigerant platform, including a CO₂ option, and is built to make the most of free cooling.

As water becomes part of how data center projects are evaluated and approved, the choice of cooling architecture is also becoming a choice about where and how a facility can operate.