Up to 25%*
Lower Energy Use
A modular cooling platform from Lennox, built for AI and high-density data centers.
PhaseFlow™ helps you direct more power to compute, reduce water dependence and scale cooling capacity as demand grows.
Lower Energy Use
Zero Operational Water Use
CO₂ and Lower-GWP Options
of Lennox Thermal Expertise
HOW PHASEFLOW WORKS
PhaseFlow™ operates in the heat rejection loop, providing a refrigerant-based platform that cools the process fluid responsible for rack-level heat removal. Unlike conventional approaches that rely on facility water and glycol infrastructure, it decouples facility heat rejection from load-side fluid requirements, so one platform serves air-cooled and liquid-cooled deployments.
THE PHASEFLOW™ ADVANTAGE
Make cooling decisions around your site, workloads and operating priorities, not the limitations of a conventional architecture.
Direct refrigerant delivery to CDUs eliminates the facility water loop, reducing cooling energy consumption by 10–25%*
Fewer heat-transfer steps than conventional chilled-water architectures
More power available for IT workloads
Additional efficiency potential with two-phase liquid cooling architectures.
Eliminate operational water use in data centers with an air-cooled configuration.
No cooling towers or water treatment in waterless configurations
Lower operating and maintenance costs
Optional low-water adiabatic configuration for additional energy efficiency
Choose from multiple refrigerant options to fit your site and sustainability objectives.
All-natural CO₂ and lower-GWP HFO/HFC refrigerant options
Flexibility to align with evolving refrigerant regulations
Avoid lock-in to a single refrigerant
CUSTOMER INNOVATION CENTER
See PhaseFlow™ operating at the Lennox Customer Innovation Center in Atlanta, Georgia. Book a half-day working session to experience a live demonstration, talk with our technical experts and explore the economics for your site.
BUILT FOR WHAT COMES NEXT
From evolving cooling strategies to growing capacity demands, PhaseFlow™ provides a future-ready, scalable and resilient platform configured around your site. Built to adapt over time, it helps protect today’s investment while preparing your cooling infrastructure for what comes next.
A single refrigerant-based facility loop supports air cooling plus single and two-phase direct-to-chip cooling strategies.
Add cooling capacity as site demand grows through a modular skid-to-plant architecture.
Configure capacity, cooling, redundancy and heat rejection to fit your site, climate and operational needs.
Accommodates different supply temperatures for air- and liquid-cooling requirements.
Provides baseline N+1 redundancy with concurrent maintainability and automated failover, with options for higher-redundancy architectures, including N+X and 2N.
CONTACT US
Tell us about your site, cooling requirements and operating priorities. A Lennox data center expert can help you evaluate where PhaseFlow™ fits and identify the right next steps.
Stay Connected With
Lennox Data Center Solutions
Expert Insights. Practical Updates.
Stay informed on emerging cooling technologies and infrastructure requirements.
Access expert perspectives on efficiency, scalability, and reliability.
Learn about new solutions, case studies, and customer success stories.
Find answers to common questions about PhaseFlow™ and data center cooling.
PhaseFlow™ is a modular, refrigerant-based cooling platform from Lennox® built for data centers facing higher heat loads, rising energy demands and evolving infrastructure needs. It supports air and liquid cooling and is designed to scale efficiently while helping reduce water dependence and support sustainability goals.